4101SN 联动警号编程
一、主机编程 1、VISTA120防区编程 |
| *下一步 #返回 新键盘按住13,输入01 |
|
|
|
|
|
**DISARMED** |
| 通电后同时按1和3,按01* 进入编程密码:41408000 |
|
READY TO ARM |
| (或者重新上电后按住“*”和“#”强制进入编程) |
|
|
|
|
|
PROGRAM MODE *Fill #view 00 |
| *93 [进入防区编程] |
|
|
|
|
|
ZONE PROGRAM? |
| 1 |
|
1=YES 0=NO |
|
|
|
|
|
|
SET TO CONFIRM? |
| 0 [地址码是否需要确定] |
|
1=YES 0=NO |
|
|
|
|
|
|
ENTER ZONE NO. |
| 011* [输入防区号码,一般从011开始] |
|
000=QUIT 001 |
|
|
|
|
|
|
011ZT P RC IN:L |
| * [防区信息] |
|
00 - -- -- - |
|
|
|
|
|
|
011 Zone Type |
| 03* [防区类型 03即时/07为24小时] |
|
NO RESPONSE 00 |
|
|
|
|
|
|
011 Vent Zone ? |
| * 不用编 |
|
011Stay Mode |
| * 不用编 |
|
011Auto-stay ? |
| * 不用编 |
|
011Silent ? |
| * 不用编 |
|
011Bypass Group |
| * 不用编 |
|
011Partition |
| * [子系统可分8个1~8,只有1个,按*号] |
|
011 REPORT CODE |
| *** [报告码,不用编] |
|
1ST 00 2ND 00 00 |
|
|
|
|
|
|
011 INPUT TYPE |
| 06* [设备类型,06总线制] |
|
NONE 00 |
| 001-009防区默认为01,为主板上防区 |
|
011Tamper Option 010 SMART CONTACT |
| * 不用编 |
|
* 不用编 |
|
010 V-PLEX RELAY? |
| 1* 启用继电器 |
|
010 Access Point |
| ** 不用编 |
|
|
|
|
|
011 INPUT S/N:L |
| 例如:1234567 * 1 [模块上的序列号] |
|
A xxx-xxxx 1 |
|
|
|
|
|
|
|
011ZT P RC IN:L |
| * [防区信息] |
|
03 1 00 SL 1 |
|
|
|
|
|
ENTER ZONE NO. |
| 000* [退出防区编程] |
|
000=QUIT 000 |
|
|
|
一、
QUIT MENU MODE |
| 1 |
1=YES 0=NO |
|
|
二、
Program Mode |
| *99 [ 退出编程] |
*Fill # View-00 |
|
|
二、继电器编程
**DISARMED** |
| 进入编程密码:41408000 |
READY TO ARM |
| (或者上电后按住“*”和“#”强制进入编程) |
|
|
|
PROGRAM MODE *Fill #view 00 |
| *93 [进入防区编程] |
|
|
|
ZONE PROGRAM? |
| 按* |
1=YES 0=NO |
|
|
一直按“*”直到显示 “OUTPUT PGM”
|
|
|
ENTER OUTPUT # |
| 1 |
00=QUIT 00 |
|
|
|
|
|
ENTER OUTPUT # |
| 01* (有几个4010i就编几个01-96) |
ZN 601 01 |
|
|
|
|
|
01 A EV ZL ZT P |
| * (第1个继电器的启动事件的参数) |
Sat 0 0 00 00 0 |
|
|
|
|
01 A EV ZL ZT P |
| * (这是第一个继电器的停止事件的参数) |
Stop 0 0 00 00 0 |
|
|
|
|
01 OUTPUTACTION |
| 2 (2=常闭) |
NO RESPONSE 0 |
|
|
|
|
01 OUTPUT ACTION |
| * |
STAY CLOSED 2 |
|
|
|
|
01 START EVENT |
| 1 (1= 报警) |
ALARM “1” |
|
|
|
01 START:ZN LIST |
| * |
00 |
|
|
|
|
01 START : ZONE # |
| 011* (模块对应的防区号) |
000 |
|
|
|
|
01 START:ZN TYPE |
| * |
NO RESPONSE 00 |
|
|
|
|
01 STOP: PAPTN |
| * |
ANY PARTITION 0 |
|
|
|
|
01 STOP: ZN LIST |
| * |
00 |
|
|
|
|
01 STOP: ZN TYPE |
| 22(22=撤防) |
DISARMING 22 |
|
|
|
|
01 STOP : PAPTN |
| * |
00 |
|
|
|
|
01 OUTPUT GROUP |
| * |
00 |
|
|
|
|
01 RESTRICTION |
| * |
1=YES 0=NO 0 |
|
|
|
|
01 OUTPUT TYPE |
| 0* |
V-PLEX 0 |
|
|
|
|
01 V-PLEX ZONE # |
| 011*(模块对应的防区号) |
000 |
|
|
|
|
01 ENTER ZN LIST? |
| 00(退出) |
00=QUIT “00” |
|
连线指导
剪断白色的跳线,在2、3端子连接10k电阻,常开(N.O.)或常闭(N.C.)设备均可使用。 4101sn外壳需要盖上,否则会报CHECK。继电器(28V,2A)
端子分配表:
1、总线(+)
2、总线(-)防区-,公共端
3、防区(+)
5、继电器 N.O.
6、继电器 N.C.
7、继电器 C
\